ISSN 2415-1297 (Online)   ISSN 2415-1300 (Print)
 
             
 
Volume : 30 Issue : 1 Year : 2023
 
Plastic Track Detectors for High Gamma Dose Measurements [Med J Islamic World Acad Sci]
Med J Islamic World Acad Sci. 1990; 3(2): 155-158

Plastic Track Detectors for High Gamma Dose Measurements

Hameed Ahmed Khan
SSNTD-Laboratory, Nuclear Engineering Division, Pakistan Institute of Nuclear Science and Technology (PINSTECH) P.O. Nilore Islamabad, Pakistan.

This paper describes (a) the calibration of Makrofol-N, LR-115, CR-39, Marofol-E, Daicel, CA80-15, and CN-85 plastic track detectors in the dose range of 103-106 Gy, and (b) applications of these detectors for high gamma dose measurement. These calibrations are based upon the changes produced in (a) the general etching velocity 'Vg' and (b) the average width of the etch pits due to fission fragments after modification by the absorbed gamma dose. The present results show that CN-85 is the most sensitive plastic track detector for gamma dose determination in the above mentioned dose range. The detectors so calibrated have been applied for the estimation of gamma doses near a spent fuel element.

Keywords: High gamma dosimetry, plastic track detectors, general etching velocity.


Hameed Ahmed Khan. Plastic Track Detectors for High Gamma Dose Measurements. Med J Islamic World Acad Sci. 1990; 3(2): 155-158