ISSN 2415-1297 (Online)   ISSN 2415-1300 (Print)
 
             
 
Volume : 30 Issue : 1 Year : 2023
 
A Comparison of The Use of Tubeless Tire Model New Generation Baska Mask ® LMA and Classic LMA in Terms of Ease-of-Use and Patient Comfort [Med J Islamic World Acad Sci]
Med J Islamic World Acad Sci. 2022; 29(1): 15-24 | DOI: 10.5505/ias.2022.58672  

A Comparison of The Use of Tubeless Tire Model New Generation Baska Mask ® LMA and Classic LMA in Terms of Ease-of-Use and Patient Comfort

Şemsi Mustafa Aksoy1, Hülya Kaşıkara2, Derya Atasever1, Levent Öztürk1, Abdulkadir But1
1Department of Anesthesiology and Reanimation, Faculty of Medicine, Ankara Yıldırım Beyazıt University, Ankara, Türkiye.
2Department of Anesthesiology and Reanimation, Ankara City Hospital, Ankara, Türkiye.

This study aimed to compare Baska Mask laryngeal mask airway (LMA) with classic LMA in terms of clinical performance, ease of use, and patient comfort. The duration of placement was compared between the groups as the primary outcome. Comparisons were also made for the number of LMA entry attempts, hemodynamic parameters. and postoperative complications. The study included 66 patients. The patients were randomly separated into two groups using the sealed-envelope method. After general anesthesia induction, a new LMA (Baska Mask) or a classic LMA was placed in the mouth of all the patients. The heart rate, blood pressure, mean and peak airway pressure, and amount of ventilation leakage were recorded throughout the surgery. The patients were examined for the presence of blood smears after removing the LMA. One hour after the surgery, an anesthetist blinded to the groups asked all the patients whether they had throat pain. The duration of LMA placement was determined as 14.5 s for classic LMA and 16.0 s for new LMA, with no significant difference between the groups (P = 0.117). The number of attempts at entry was similar in both groups (P = 0.741). The mean and peak airway pressure measurements 5 min after LMA placement were statistically significantly different between the groups (P < 0.05), with higher values in the new LMA group. No blood smears were observed in the patients using new LMA, while blood smears were determined in seven patients in the classic LMA group (P = 0.012). The results of this study showed that an adequate, safe open airway was provided throughout the surgery in both groups. Despite no significant difference with respect to ease of use, the Baska Mask was thought to be more advantageous than LMA in terms of patient comfort.

Keywords: Baska Mask LMA, Classic LMA, general anesthesia, LMA placement duration, tubeless tire model


Şemsi Mustafa Aksoy, Hülya Kaşıkara, Derya Atasever, Levent Öztürk, Abdulkadir But. A Comparison of The Use of Tubeless Tire Model New Generation Baska Mask ® LMA and Classic LMA in Terms of Ease-of-Use and Patient Comfort. Med J Islamic World Acad Sci. 2022; 29(1): 15-24

Corresponding Author: Şemsi Mustafa Aksoy, Türkiye


TOOLS
Full Text PDF
Print
Download citation
RIS
EndNote
BibTex
Medlars
Procite
Reference Manager
Share with email
Share
Send email to author

Similar articles
PubMed
Google Scholar




   
Copyright © 2024 medicaljournal-ias.org. All Rights Reserved.