ISSN 2415-1297 (Online)   ISSN 2415-1300 (Print)
 
             
 
Volume : 30 Issue : 1 Year : 2023
 
Comparison of the accuracy of isosulfan blue and technetium-99m lymphoscintigraphy to determine axillary lymph node metastasis in breast cancer [Med J Islamic World Acad Sci]
Med J Islamic World Acad Sci. 2017; 25(3): 72-80 | DOI: 10.5505/ias.2017.89166  

Comparison of the accuracy of isosulfan blue and technetium-99m lymphoscintigraphy to determine axillary lymph node metastasis in breast cancer

Özgür Albuz1, Gökhan Akkurt1, Aslı Ayan2, Erkan Öztürk3, Müjdat Balkan4
1Department of General Surgery, Keçiören Education and Research Hospital, Ankara, Turkey.
2Department of Nuclear Medicine, Gulhane Education and Research Hospital, Ankara, Turkey.
3Department of General Surgery, Medicana International Hospital, Ankara, Turkey.
4Department of General Surgery, Faculty of Medicine, Tobb University of Economics and Technology, Ankara, Turkey.

This study aimed to compare the efficiency of isosulfan blue (ISB) and colloid methods in determining metastatic conditions of axillary lymph node in sentinel lymph node biopsy (SLNB). This prospective study was performed between April 2005 and July 2009 at Gulhane Medical Faculty, Department of General Surgery. A total of 102 female patients diagnosed with breast cancer were enrolled in the clinic of Gulhane School of Medicine. According to the diagnostic protocols of SLN, the patients were divided into three groups as follows: ISB (group I), colloid (group II), and ISB and colloid (group III). SLN was identified in 49 of 52 patients (94.2%) in the ISB group; the sensitivity, specificity, negative predictive value (NPV), positive predictive value (PPV), and false negativity (FN) ratio were found to be 90.9%, 75.8%, 96.1%, 55.5%, and 9.1%, respectively. On the contrary, the sentinel lymph node was identified in 38 of 38 (100%) patients in the colloid group; the sensitivity, specificity, PPV, NPV, and FN were found to be 88.2%, 100%, 100%, 91.3%, and 11.8%, respectively. In ISB and colloid groups; SLN was identified in 12 of 12 (100%) patients in the ISB and colloid groups; the sensitivity, specificity, PPV, NPV, and FN were found to be 100%, 100%, 100%, and 0%, respectively. This study showed that the combined methods applied to heterogeneous groups of patients for SLNB in breast cancer cases were minimally invasive and effective and hence could be used for evaluating nodal metastases.

Keywords: Isosulfan blue, sentinel node, Tc-99m sulfur colloid


Özgür Albuz, Gökhan Akkurt, Aslı Ayan, Erkan Öztürk, Müjdat Balkan. Comparison of the accuracy of isosulfan blue and technetium-99m lymphoscintigraphy to determine axillary lymph node metastasis in breast cancer. Med J Islamic World Acad Sci. 2017; 25(3): 72-80

Corresponding Author: Özgür Albuz, Türkiye


TOOLS
Full Text PDF
Print
Download citation
RIS
EndNote
BibTex
Medlars
Procite
Reference Manager
Share with email
Share
Send email to author

Similar articles
PubMed
Google Scholar




   
Copyright © 2024 medicaljournal-ias.org. All Rights Reserved.